Addr Name Bit Description HW Reset
Value
Access
0x340 PHY_REFCLK_
KHZ
[31:0] Reference clock frequency in KHz, assuming
the clk_status clock has the frequency of
100 MHz. The reference clock frequency is
the value in the PHY_REFCLK_KHZ register
times the frequency of the clk_status clock,
divided by 100.
RO
0x341 PHY_RXCLK_
KHZ
[31:0] RX clock (clk_rxmac) frequency in KHz,
assuming the clk_status clock has the
frequency of 100 MHz. The RX clock
frequency is the value in the PHY_REFCLK_KHZ
register times the frequency of the clk_
status clock, divided by 100.
RO
0x342 PHY_TXCLK_
KHZ
[31:0] TX clock (clk_txmac) frequency in KHz,
assuming the clk_status clock has the
frequency of 100 MHz. The TX clock
frequency is the value in the PHY_REFCLK_KHZ
register times the frequency of the clk_
status clock, divided by 100.
RO
0x343 PHY_RECCLK_
KHZ
[31:0] RX recovered clock frequency in KHz,
assuming the clk_status clock has the
frequency of 100 MHz. The RX recovered
clock frequency is the value in the PHY_
REFCLK_KHZ register times the frequency of
the clk_status clock, divided by 100.
RO
0x344 PHY_
TXIOCLK_KHZ
[31:0] TX PMA clock frequency in KHz, assuming
the clk_status clock has the frequency of
100 MHz. The TX PMA clock frequency is
the value in the PHY_REFCLK_KHZ register
times the frequency of the clk_status clock,
divided by 100.
RO
Link Fault Signaling Registers
Table 3-21: LINK_FAULT_CONFIG Register—Offset 0x405
Name Bit Description
Reset
Value
Access
Unidir Enable [1]
When asserted, the IP core includes Clause 66 support for
remote link fault reporting on the Ethernet link.
1'b0
RW
Link Fault
Reporting
Enable
[0]
When asserted, the PCS generates remote fault sequence
on the Ethernet link, if conditions are met.
1’b1 RW