5–8 Chapter 5: Functional Description—ALTMEMPHY
Block Description
External Memory Interface Handbook Volume 3 June 2011 Altera Corporation
Section I. DDR and DDR2 SDRAM Controllers with ALTMEMPHY IP User Guide
For full-rate clock and reset management refer to Table 54. The PLL is configured
exactly in the same way as in half-rate designs. The PLL information and restriction
from half-rate designs also applies.
1 The
phy_clk_1x
clock is now full-rate, despite the “
1x
” naming convention.
You must choose a PLL and PLL input clock pin that are located on the same side of
the memory interface to ensure minimal jitter. Cascaded PLLs are not recommended
for DDR/DDR2 SDRAM interfaces as jitter can accumulate with the use of cascaded
PLLs causing the memory output clock to violate the memory device jitter
specification. Also, ensure that the input clock to the PLL is stable before the PLL
locks. If not, you must perform a manual PLL reset and relock the PLL to ensure that
the phase relationship between all PLL outputs are properly set. The PLL restrictions
in half-rate designs also applies to full-rate designs.
Half-rate
and full rate
ac_clk_2x
0,
90,180
, 270
Full-Rate Global
The
ac_clk_2x
clock is
derived from either
mem_clk_2x
(when you
choose 0 or 180 phase
shift) or
write_clk_2x
(when you choose 90 or
270 phase shift). Refer
to “Address and
Command Datapath” on
page 5–3 for illustrations
of the address and
command clock
relationship with the
mem_clk_2x
or
write_clk_2x
signals.
Notes to Table 5–4:
(1) In full-rate designs a
_1x
clock may run at full rate clock.
(2) This clock should be of the same clock network clock as the
resync_clk_2x
clock.
Table 5–1. DDR/DDR2 SDRAM Clocking in Arria GX, HardCopy II, Stratix II, and Stratix II GX Devices (Part 3 of 3)
Design
Rate
Clock Name
Postscale
Counter
Phase
(Degrees)
Clock Rate
Clock
Network Type
Notes