Throughput Optimization
12
2015.05.14
UG-01145_avmm
Subscribe
Send Feedback
The PCI Express Base Specification defines a flow control mechanism to ensure efficient transfer of TLPs.
Each transmitter, the write requester in this case, maintains a credit limit register and a credits
consumed register. The credit limit register is the sum of all credits received by the receiver, the write
completer in this case. The credit limit register is initialized during the flow control initialization phase
of link initialization and then updated during operation by Flow Control (FC) Update DLLPs. The
credits consumed register is the sum of all credits consumed by packets transmitted. Separate credit
limit and credits consumed registers exist for each of the six types of Flow Control:
Posted Headers
Posted Data
Non-Posted Headers
Non-Posted Data
Completion Headers
Completion Data
Each receiver also maintains a credit allocated counter which is initialized to the total available space
in the RX buffer (for the specific Flow Control class) and then incremented as packets are pulled out of
the RX buffer by the Application Layer. The value of this register is sent as the FC Update DLLP value.
©
2015 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, ENPIRION, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words and logos are
trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other words and logos identified as
trademarks or service marks are the property of their respective holders as described at www.altera.com/common/legal.html. Altera warrants performance
of its semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any
products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information,
product, or service described herein except as expressly agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device
specifications before relying on any published information and before placing orders for products or services.
ISO
9001:2008
Registered
www.altera.com
101 Innovation Drive, San Jose, CA 95134
Seitenansicht 142
1 2 ... 138 139 140 141 142 143 144 145 146 147 148 ... 211 212

Kommentare zu diesen Handbüchern

Keine Kommentare