Bits Register Description Reset Value Access
[6] Mask for Corrected Internal Error reported by the Application
Layer.
1 RWS
[5] Mask for configuration error detected in CvP mode. 0 RWS
[4:2] Reserved. 0 RO
[1] Mask for retry buffer correctable ECC error. 1 RWS
[0] Mask for RX Buffer correctable ECC error. 1 RWS
Correctable Internal Error Status Register
Table 6-30: Correctable Internal Error Status Register
The Correctable Internal Error Status register reports the status of the internally checked errors that are
correctable. When these specific errors are enabled by the Correctable Internal Error Mask register, they are
forwarded as Correctable Internal Errors as defined in the PCI Express Base Specification 3.0. This register is for
debug only. It should only be used to observe behavior, not to drive logic custom logic.
Bits Register Description Reset Value Access
[31:6] Reserved. 0 RO
[5] When set, indicates a configuration error has been detected in
CvP mode which is reported as correctable. This bit is set
whenever a CVP_CONFIG_ERROR occurs while in CVP_MODE.
0 RW1CS
[4:2] Reserved. 0 RO
[1] When set, the retry buffer correctable ECC error status indicates
an error.
0 RW1CS
[0] When set, the RX buffer correctable ECC error status indicates an
error.
0 RW1CS