3–12 Chapter 3: Parameter Settings
Error Management Registers Settings
RapidIO II MegaCore Function August 2014 Altera Corporation
User Guide
■ If you do not instantiate the Error Management Extension registers (refer to “Error
Management Registers Settings” on page 3–12), this parameter determines the
value of the
EF_PTR
field of the
LP-Serial Lane Extended Features Block Header
register at offset 0x200 (Table 6–16 on page 6–21).
■ If you instantiate the Error Management Extension registers in your RapidIO II IP
core variation, this parameter determines the value of the
EF_PTR
field of the
Error
Management Extensions Block Header
register at offset 0x300 (Table 6–66 on
page 6–43).
1 This parameter does not affect the
Assembly Information
CAR. The
ExtendedFeaturesPtr
in the
Assembly
Informatio
n CAR is set to the value of 0x100,
which is the offset for the LP-Serial Extended Features block (refer to Table 6–2 on
page 6–2).
Error Management Registers Settings
The Error Management Registers tab lists a single parameter, Enable error
management extension registers.
If you turn on Enable error management extension registers, your RapidIO II IP core
instantiates the Error Management Extensions register block defined in the RapidIO
Interconnect Specification Part 8: Error Management Extensions Specification.
The RapidIO II IP core instantiates these registers at register block offset 0x300. If you
do not instantiate these registers, you can specify user-defined registers at offset
0x300.
The RapidIO II IP core Error Management registers are described in “Error
Management Registers” on page 6–42.