Altera RapidIO II MegaCore Function Bedienungsanleitung Seite 39

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 218
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 38
Chapter 3: Parameter Settings 3–9
Capability Registers Settings
August 2014 Altera Corporation RapidIO II MegaCore Function
User Guide
Port Number
Port number sets the
PortNumber
field of the
Switch
Port
Information
CAR. This
value is the number of the port from which the
MAINTENANCE
read operation accesses
this register.
Switch Route Table Destination ID Limit CAR
The Switch Route Table Destination ID Limit CAR is described in Table 6–30 on
page 6–31.
Switch Route Table Destination ID Limit
Switch route table destination ID limit sets the
Max_destID
field of the
Switch
Route
Table Destination ID Limit
CAR.
Data Streaming Information CAR
The
Data Streaming Information
CAR is described in Table 6–31 on page 6–31.
Maximum PDU
Maximum PDU sets the
MaxPDU
field of the
Data Streaming Information
CAR.
Number of Segmentation Contexts
Number of segmentation contexts sets the
SegSupport
field of the
Data Streaming
Information
CAR.
Source Operations CAR
The Source operations CAR override parameter supports user input to the values of
all of the fields of the
Source Operations
CAR (Table 6–28 on page 6–29). You can use
this parameter to specify that your RapidIO II IP core variation handles some specific
functionality through the Avalon-ST pass-through port.
The 32-bit default value of the
Source Operations
CAR is determined by the
functionality you enable in the RapidIO II IP core with other settings in the parameter
editor. For example, if you turn on Enable Maintenance module, the
PORT_WRITE
field
is set by default to the value of 1’b1. However, the actual reset value of the
Source
Operations
CAR is the result of the bitwise exclusive-or operation applied to the
default values and the value you specify for the Source operations CAR override
parameter.
For example, by default, the
Data Message
field of this CAR is turned off. However,
you can set the value of the Source operations CAR override parameter to
32’h00000800 to override the default value of the
Data Message
field, to indicate that
user logic attached to the Avalon-ST pass-through interface supports data message
operations. The RapidIO II IP core supports reporting of data-message related errors
through the standard Error Management Extensions registers.
Seitenansicht 38
1 2 ... 34 35 36 37 38 39 40 41 42 43 44 ... 217 218

Kommentare zu diesen Handbüchern