Seitenansicht 26
Altera Corporation 3–1
Chapter 3. Design Case
Exceptions
Multiple Clock
Uncertainty on a
Single Clock
Transfer
In real designs, there are some special cases for calculating clock
uncertainty values that require extra steps.
Figure 3–1 shows a design with both I/O transfer and intra-clock
transfer. In this case, there are two possible clock uncertainties (I/O and
data paths) for the same clock transfer.
Figure 3–1. Circuit with Intra-Clock Transfer and I/O Interface
To set the clock uncertainty constraints correctly, you should create a
virtual clock for the circuit. The following code example shows the SDC
used to constrain the design, as shown in Figure 3–1:
Example 3–1. SDC Constraints for i/O
create_clock –name CLK1 –period 10 [get_ports {CLK1}]
create_clock –name VIRTUAL_CLK –period 10
set_input_delay –max –clock VIRTUAL_CLK 8.00 [get_ports {DIN1}]
set_input_delay –min –clock VIRTUAL_CLK 2.00 [get_ports {DIN1}]
set_clock_uncertainty –from CLK1 –to CLK1 –setup 0.200
set_clock_uncertainty –from CLK1 –to CLK1 –hold 0.050
set_clock_uncertainty –from VIRTUAL_CLK1 –to CLK1 –setup 0.180
set_clock_uncertainty –from VIRTUAL_CLK1 –to CLK1 –hold 0.180
Clock Transfer Type
Setup CU (ps) Hold CU (ps)
Intra-Clock
Inter-Clock
I/O Interface
With PLL
Without PLL
With PLL
With PLL
330
350
150
50
330
350
150
100
Without PLL
200
50
Without PLL
180 180