DescriptionValueName
A 4-bit value that defines the reset value for a
nanosecond of period.
The default value is 4'h6 to capture 6.4ns for
156.25 MHz frequency. For 125 MHz frequency
(1G), set this parameter to 4'h8.
Between 0 and 4hFPERIOD_NSEC
A 4-bit value that defines the reset value for a
fractional nanosecond of period.
The default value is 16'h6666 to capture 0.4ns
of 6.4ns for 156.25 MHz frequency. For 125
MHz frequency (1G), set this parameter to 16'h0.
Between 0 and 16hFFFFPERIOD_FNSEC
ToD Synchronizer Signals
ToD Synchronizer Common Clock and Reset Signals
Table D-3: Clock and Reset Signals for the ToD Synchronizer
DescriptionWidthDirectionSignal
Clock from master ToD domain.1Inputclk_master
Reset signal that is synchronized to the master
ToD clock domain.
1Inputreset_master
Clock from slave ToD domain.1Inputclk_slave
Reset signal that is synchronized to the slave
ToD clock domain.
1Inputreset_slave
Sampling clock to measure the latency across
the ToD Synchronizer.
1Inputclk_sampling
ToD Synchronizer Interface Signals
Table D-4: Interface Signals for the ToD Synchronizer
DescriptionWidthDirectionSignal
Assert this signal to start the ToD synchroniza-
tion process. When this signal is asserted, the
synchronization process continues and the time
of day from the master ToD clock domain will
be repeatedly synchronized with the slave ToD
clock domain.
1Inputstart_tod_sync
ToD Synchronizer
Altera Corporation
Send Feedback
UG-01008
ToD Synchronizer Signals
D-4