Mentor Verification IP AE AXI4-Lite User Guide, V10.3
340
VHDL Tutorials
Verifying a Master DUT
April 2014
m_rd_data_phase_ready_delay variable. The whole process runs concurrently with other
processes in the test program, using the path_id = AXI4_PATH_6. See “Overloaded Procedure
Common Arguments” on page 151 for details of path_id, and is similar in operation to the
handle_write_resp_ready procedure. Refer to “AXI4-Lite VHDL Master BFM Test Program”
on page 397 for the complete handle_read_data_ready code listing.
Verifying a Master DUT
A master DUT component is connected to a slave BFM at the signal-level. A slave test program,
written at the transaction-level, generates stimulus via the slave BFM to verify the master DUT.
Figure 11-2 illustrates a typical top-level test bench environment.
Figure 11-2. Master DUT Top-Level Test Bench Environment
In this example, the slave test program is a simple memory model.
A top-level file instantiates and connects all the components required to test and monitor the
DUT, and controls the system clock (ACLK) and reset (ARESETn) signals.
Slave
BFM
Master
DUT
Slave test program
Top-level file