a. Double-click in the Assignment Name column and scroll to the bottom of the available
assignments.
b. Select VCCA_GXB Voltage.
c. In the Value column, select 3_0V from the list.
The Quartus II software adds these instance assignments commands to the .qsf file for your project.
You can also enter these commands at the Quartus II Tcl Console. For example, the following command
sets the XCVR_VCCR_VCCT_VOLTAGE to 1.0 V for the pin specified:
set_instance_assignment -name XCVR_VCCR_VCCT_VOLTAGE 1_0V to “pin”
Related Information
Stratix V Device Datasheet
Stratix E, GS, and GX Device Family Pin Connection Guidelines
Recommended Reset Sequence to Avoid Link Training Issues
Successful link training can only occur after the FPGA is configured and the Transceiver Reconfiguration
Controller IP Core has dynamically reconfigured SERDES analog settings to optimize signal quality. For
designs using CvP, link training occurs after configuration of the I/O ring and Hard IP for PCI Express IP
Core. Refer to Reset Sequence for Hard IP for PCI Express IP Core and Application Layer for a description
of the key signals that control reset, control dynamic reconfiguration, and link training. Altera
recommends separate control of reset signals for the Endpoint and Root Port. Successful reset sequence
includes the following steps:
1. Wait until the FPGA is configured as indicated by the assertion of CONFIG_DONE from the FPGA block
controller.
2. Deassert the mgmt_rst_reset input to the Transceiver Reconfiguration Controller IP Core.
3. Wait for tx_cal_busy and rx_cal_busy SERDES outputs to be deasserted.
4. Wait 1 ms after the assertion of CONFIG_DONE, then deassert the Endpoint reset.
5. Wait approximately 100 ms, then deassert the Root Port reset.
6. Deassert the reset output to the Application Layer.
Figure 10-1: Recommended Reset Sequence
CONF_DONE
Endpoint Reset
Root Port Reset
1 ms
100 ms
10-2
Recommended Reset Sequence to Avoid Link Training Issues
UG-01097_sriov
2014.12.15
Altera Corporation
Design Implementation
Send Feedback
Seitenansicht 136