Parameter Name Type Required Description
INPUT_B[0 … 3]_LATENCY_CLOCK String No Specifies the clock signal for the pipeline
register on the corresponding datab[] port.
Values are UNREGISTERED, CLOCK0, CLOCK1,
and CLOCK2. If omitted, the default value is
UNREGISTERED.
INPUT_B[0…3]_LATENCY_ACLR String No Specifies the asynchronous clear signal for
the pipeline register on the corresponding
datab[] port. Values are NONE, ACLR0,
ACLR1. If omitted, the default value is NONE.
INPUT_C[0 … 3]_LATENCY_CLOCK String No Specifies the clock signal for the pipeline
register on the corresponding datac[] port.
Values are UNREGISTERED, CLOCK0, CLOCK1,
and CLOCK2. If omitted, the default value is
UNREGISTERED.
INPUT_C[0…3]_LATENCY_ACLR String No Specifies the asynchronous clear signal for
the pipeline register on the corresponding
datac[] port. Values are NONE, ACLR0,
ACLR1. If omitted, the default value is NONE.
COEFFSEL[0…3]_LATENCY_CLOCK String No Specifies the clock signal for the pipeline
register on the corresponding coefficient
inputs. Values are UNREGISTERED, CLOCK0,
CLOCK1, and CLOCK2.
COEFFSEL[0…3]_LATENCY_ACLR String No Specifies the asynchronous clear signal for
the pipeline register on the corresponding
coefficient inputs. Values are NONE, ACLR0
and ACLR1. If omitted, the default value is
NONE.
SIGNED_LATENCY_CLOCK_[] String No Parameter [A, B]. Specifies the clock signal
for the pipeline register on the
corresponding sign[] port. Values are
UNREGISTERED, CLOCK0, CLOCK1, and
CLOCK2. If omitted, the default value is
UNREGISTERED.
SIGNED_LATENCY_ACLR_[] String No Parameter [A, B]. Specifies the asynchro‐
nous clear signal for the pipeline register on
the corresponding sign[] port. Values are
NONE, ACLR0, and ACLR1. If omitted the
default value is NONE.
ADDNSUB_MULTIPLIER_LATENCY_
CLOCK[]
String No Parameter [1, 3]. Specifies the clock signal
for the pipeline register on the
corresponding addnsub[] input. Values are
UNREGISTERED, CLOCK0, CLOCK1 and CLOCK2.
If omitted, the default value is UNREGIS-
TERED.