Table 9-8: ALTMULT_ADD Megafunction Parameters (Stratix II, Stratix III, and Stratix IV Devices Only)
Parameter Name Type Requi
red
Description
OUTPUT_SATURATE_TYPE String No Specifies the saturation mode.
Values are SYMMETRIC and
ASYMMETRIC. A value of
SYMMETRIC specifies the absolute
value of the maximum negative
number equal to the maximum
positive number. A value of
ASYMMETRIC specifies the
maximum negative number is
larger than the maximum
positive number. If omitted, the
default value is ASYMMETRIC.
WIDTH_SATURATE_SIGN
String No Specifies the saturation position.
The value is determined by
counting the bits that become the
sign bits after saturation. Values
are calculated according to the
following modes- WIDTH_A,
WIDTH_B, and WIDTH_RESULT.
Value must be an unsigned
integer. If a positive number is
unavailable, no saturation is
allowed in your input/output
width and mode setting. If
omitted, the default value is 1.
CHAINOUT_ADDER
String No Specifies the chainout mode of
the final adder stage. Values are
YES and NO. If omitted, the
default value is NO.
ACCUMULATOR String No Specifies the accumulator mode
of the final adder stage. Values
are YES and NO. If omitted, the
default value is NO. When value is
set to YES, rounding is dynamic
and you must initialize the
accumulator while rounded data
is acquired.
Table 9-9: ALTMULT_ADD Megafunction Parameters (Stratix III and Stratix IV Devices Only )
Parameter Name Type Requi
red
Description
WIDTH_CHAININ Integer No Width of the chainin[] port.
WIDTH_CHAININ equals WIDTH_
RESULT if port chainin is used. If
omitted, the default value is 1.
UG-01063
2014.12.19
ALTMULT_ADD Parameters
9-25
ALTMULT_ADD (Multiply-Adder)
Altera Corporation
Send Feedback