3–4 Chapter 3: External Memory BFM
Parameters
Avalon Verification IP Suite User Guide May 2011 Altera Corporation
Interface Signals Name
Address Role cdt_address
Specifies the conduit interface role name that
matches the role name on the external memory
device.
Data Role cdt_data_io
Write Role cdt_write
Read Role cdt_read
Byteenable Role cdt_byteenable
Chip Select Role cdt_chipselect
Outputenable Role cdt_outputenable
Begintransfer Role cdt_begintransfer
Reset Role cdt_reset
Port Widths
Address width 8 1–32 Specifies the address width in bits.
Symbol width 8 1–1024 Specifies the data symbol width in bits.
Number of symbols 4
1, 2, 4, 8,
16, 32, 64,
128
Specifies the number of symbols in a data.
Memory Contents
Memory Initialization
altera_external_memory_
bfm.hex
Specifies the file to initialize the memory
content at the beginning of the simulation. The
BFM supports only one memory file.
Interface Timing
Read Latency of Interface 0 Specifies the read latency of the interface.
Table 3–2. External Memory BFM Parameter Settings (Part 2 of 2)
Option Default Value
Legal
Values
Description