read_
para
m
write
_
para
m
read_source param Remote Update Operation data_out
width
(bits)
MSM Mode
0 1 [00] [011]
Write the watchdog enable bit.
All parameters can be written in factory
mode only.
1 Factory
0 1 [00] [100]
Write application boot address.
All parameters can be written in factory
mode only.
22 Factory
0 1 [00] [110] Write to force the internal oscillator as
startup state machine clock. All parameters
can be written in factory mode only.
1 Factory
1 0 [11] [001] Read the early confdone check bits 1 Factory
1 0 [11] [010] Read watchdog time-out value 12 Factory
1 0 [11] [011] Read watchdog enable bit 1 Factory
1 0 [11] [100] Read boot address 22 Factory
1 0 [11] [110] Read to check whether the internal oscillator
is set as startup state machine clock
1 Factory
read_source
The following table lists the details for read_source. read_source specifies whether a parameter value is
read from the current or a previous state. When you trigger the read operation, all contents in status
register or input register latched to the data_out node in the Altera Remote Update IP core.
Table 14: read_source
read_source Description
00 Current state contents in status register
01 Previous state register 1 contents in status register
10 Previous state register 2 contents in status register
11 Current contents is in input register
State Register
The previous state register 1 reflects the current application configuration and the previous state register 2
reflects the previous application configuration.
UG-31005