Altera Remote Update IP Core Bedienungsanleitung Seite 36

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 43
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 35
read_
para
m
write
_
para
m
read_source param Remote Update Operation data_out
width
(bits)
MSM Mode
1 0 [00] [000] Master State Machine Current State Mode
(Read Only)
00—Factory mode
01—Application mode
11—Application mode with Master State
Machine User Watchdog Timer Enabled
2 Factory or
Application
1 0 [00] [100] Read factory boot address 24 Factory
1 0 [01] [100]
Read Past Status 1 boot address.
For more information, refer to Figure 11.
24 Factory
1 0 [01] [111]
Read Past Status 1 reconfiguration trigger
condition source.
For more information, refer to Figure 11.
5 Factory
1 0 [10] [100]
Read Past Status 2 boot address.
For more information, refer to Figure 11.
24 Factory
1 0 [10] [111]
Read Past Status 2 reconfiguration trigger
condition source
For more information, refer to Figure 11.
5 Factory
1 0 [01] [010] Read current application mode watchdog
value
29 Application
1 0 [01] [011] Read current application mode watchdog
enable
1 Application
1 0 [10] [100] Read current application mode boot address 24 Application
0 1 [00] [001]
Write the early confdone check bit.
All parameters can be written in factory
mode only.
1 Factory
0 1 [00] [010]
Write the watchdog time-out value.
All parameters can be written in factory
mode only.
12 Factory
36
Remote Update Operation
UG-31005
2015.04.07
Altera Corporation
Altera Remote Update IP Core User Guide
Send Feedback