GUI Name Legal Value in GUI Description
Which configuration
device will you be using?
EPCS device
EPCQ device
Choose the configuration device that you are using.
Add support for writing
configuration parameters
Enable this if you need to write configuration
parameters.
Enable reconfig POF
checking
Allows you to enable .pof checking, which allows the
remote update block to verify the existence of an
application configuration image before the image is
loaded. When you turn on this parameter, the Altera
Remote Update IP core checks the .pof and sends the
reconfig signal. This option is disabled by default.
Ports
Table 12: Altera Remote Update IP Core Ports for Cyclone IV Devices
Name Port Required
?
Description
read_param
Input
No Read signal for the parameter specified in
param[] input port and fed to data_out[]
output port.
Signal indicating the parameter specified on the
param[] port should be read. The number of bits
set on data_out[] depends on the parameter
type. The signal is sampled at the rising clock
edge. Assert the signal for only one clock cycle to
prevent the parameter from being read again in a
subsequent clock cycle.
The busy signal is activated as soon as read_
param is read as active. While the parameter is
being read, the busy signal remains asserted, and
data_out[] has invalid data. When the busy
signal is deactivated, data_out[] is valid,
another parameter can be read.