Bit Parameter Width Comments
010 Watchdog Timeout Value 12
011 Watchdog Enable 1
100 Page Select 32
For the Quartus II software version 14.0 and onwards:
Width of 32 when reading and writing the start
address.
For active serial devices using 32-bit addressing,
such as EPCQL-256, PGM[31..2] corresponds to
the upper 30 bits of the 32-bits start address.
PGM[1..0] is read as 2'b0.
101 Configuration Mode (AnF) 1
In local update mode, this parameter can only be read.
This parameter is set to 1 in application page and is set
to 0 in factory page. In remote update mode, this
parameter can be read and written.
Before loading the application page in remote update
mode, Altera recommends that you set this parameter
to 1. The content of the control register cannot be read
properly if you fail to do so.
110 Illegal Value
111 Illegal Value
Arria II, Arria V, Cyclone V, Stratix IV, and Stratix V Devices
This section covers the remote system configuration modes, components, parameter, ports, and
parameter settings for Arria II, Arria V, Cyclone
®
V, Stratix
®
IV, and Stratix V devices.
Remote System Configuration Mode
Arria II, Arria V, Cyclone V, Stratix IV, and Stratix V devices support remote configuration mode only.
UG-31005
2015.04.07
Arria II, Arria V, Cyclone V, Stratix IV, and Stratix V Devices
15
Altera Remote Update IP Core User Guide
Altera Corporation
Send Feedback