Parameter CLI Parameter
Description
Name Legal
Values
Name Legal
Values
Create an
asynchronous
clear port
On/Off clr — Specifies whether to turn on
the asynchronous clear (clr)
port.
Turn on this option when you
want to reset the Altera
Temperature Sensor IP core.
When you turn off this
option, the clear port
automatically connects to
GND.
Altera Temperature Sensor Signals
The following tables list the Altera Temperature Sensor IP core signals.
Table 4: Altera Temperature Sensor IP Core Signals for Arria 10 Devices
Signals Direction Width (Bit) Description
corectl Input 1 Enables the temperature sensing feature by the IP
core.
reset Input 1 Resets the temperature sensing block.
tempout[9:0] Output 10 10-bit output data from internal ADC circuitry of
temperature sensor block.
eoc Output 1 Indicates end of internal ADC conversion. This
signal goes high for one clock cycles and you can
latch the data on tempout at the falling edge of EOC.
Table 5: Altera Temperature Sensor IP Core Signals for Suppported Devices
Signals Direction Width (Bit) Description
clk Input 1 Input clock signal that runs at a frequency of
80 MHz and below. The internal clock divider
reduces the frequency of the clk signal to 1 MHz or
less before clocking the ADC.
ce Input 1 The asynchronous clock enable signal for the clk
signal. This signal turns on/off the Altera Tempera‐
ture Sensor IP core that implements the TSD block.
This is an active-high signal. By default, this port
connects to VCC.
8
Altera Temperature Sensor Signals
UG-01074
2015.05.04
Altera Corporation
Altera Temperature Sensor IP Core User Guide
Send Feedback