Temperature Sensing Operation for Arria V, Arria V GZ, Stratix IV, and Stratix V
Devices
Figure 2: Altera Temperature Sensor Block Diagram
This figure shows the top-level ports and the basic building blocks of the Altera Temperature Sensor IP
core.
ce
tsdcalo[7:0]
clr
tsdcaldone
clk
Altera Temperature Sensor IP Core
TEMPERATURE
SENSOR
adcclk
CLOCK
DIVIDER
ADC
oe
The Altera Temperature Sensor IP core runs at the frequency of the clk signal. The clk signal can run at a
frequency of 80 MHz and below. The clock divider divides the clk signal to 1 MHz or less to feed the
ADC. You can set the value of the clock divider using the Altera Temperature Sensor IP core parameter
editor.
The ce signal connects to the output enable (oe) port of the clock divider block. Assert the ce signal to
enable the Altera Temperature Sensor IP core. When you deassert the ce signal, the IP core disables the
ADC, and maintains the previous values of the tsdcalo[7..0] and tsdcaldone signals unless you assert
the clr signal, or reset the device. The clr signal is asynchronous, and you must assert the clr signal at
least one clock cycle of the adcclk signal to clear the output ports.
Enabling the ADC allows you to measure the device temperature only once. To perform another tempera‐
ture measurement, assert the clr signal, or reset the device. The clr signal is asynchronous, and you must
assert the clr signal at least one clock cycle of the ADC clk signal to clear the output ports.
Note:
When you choose not to create the ce port, the IP core connects the ce port to VCC. In this case,
the ADC circuitry is always enabled. Altera recommends that you disable the ADC by deasserting
the ce signal when the ADC is not in use to reduce power consumption.
During device power-up or when you assert the asynchronous clr signal, the Altera Temperature Sensor
IP core sets the tsdcaldone port to 0 and the tsdcalo[7:0] signal to 11010101 or 0xD5. After 10 clock
cycles of the adcclk signal, the Altera Temperature Sensor IP core asserts the tsdcaldone signal to
indicate that the temperature sensing operation is complete and that the value of the tsdcalo[7:0] signal
is valid. The value of the tsdcalo[7:0] signal corresponds to the device temperature range. For more
information about the value of tsdcalo[7:0] signals, refer to the Related Information. To start another
temperature sensing operation, assert the clr signal for at least one clock cycle of the adcclk signal, or
reset the device.
UG-01074
2015.05.04
Temperature Sensing Operation for Arria V, Arria V GZ, Stratix IV, and Stratix V
Devices
3
Altera Temperature Sensor IP Core User Guide
Altera Corporation
Send Feedback