Altera Mentor Verification IP Altera Edition AMBA AXI3/4T Bedienungsanleitung Seite 602

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 783
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 601
Mentor VIP AE AXI3/4 User Guide, V10.2b
582
VHDL AXI3 and AXI4 Monitor BFMs
get_write_addr_phase()
September 2013
get_write_addr_phase()
This blocking procedure gets a write address phase that is uniquely identified by the
transaction_id argument previously created by the create_monitor_transaction() procedure.
AXI3 Example
-- Create a monitor transaction. Creation returns tr_id to identify
-- the transaction.
create_monitor_transaction(tr_id, bfm_index, axi_tr_if_0(bfm_index));
....
-- Get the write address phase of the tr_id transaction.
get_write_addr_phase(tr_id, bfm_index, axi_tr_if_0(bfm_index));
Prototype
-- * = axi| axi4
-- ** = AXI | AXI4
procedure get_write_addr_phase
(
transaction_id : in integer;
bfm_id : in integer;
path_id : in *_path_t; -- Optional
signal tr_if : inout *_vhd_if_struct_t
);
Arguments
transaction_id Transaction identifier. Refer to “Overloaded Procedure
Common Arguments” on page 203 for more details.
bfm_id BFM identifier. Refer to “Overloaded Procedure Common
Arguments” on page 203 for more details.
path_id (Optional) Parallel process path identifier:
**_PATH_0
**_PATH_1
**_PATH_2
**_PATH_3
**_PATH_4
Refer to “Overloaded Procedure Common Arguments” on
page 203 for more details.
tr_if Transaction signal interface. Refer to “Overloaded
Procedure Common Arguments” on page 203 for more
details.
Returns
None