
ALTDQ_DQS2 PLL and DLL Ports
Table 9: ALTDQ_DQS2 PLL and DLL Ports
Port name Type Width Description
dll_delayctrl_in[]
Input 7 Receives the 7-bit delay settings
from the dll_delayctrlout port of
the ALTDLL instance. This 7-bit
signal controls delay through the
DQS delay chains. Compilation
error occurs if this port is not
connected to a DLL.
This port is supported in Arria V,
Cyclone V, and Stratix V devices.
fr_clock_in
Input 1 Receives the full-rate clock signal
from a clock pin, or the PLL clock
output port.
This port is supported in Arria V,
Cyclone V, and Stratix V devices.
hr_clock_in
Input 1 Receives the half-rate clock signal
from a clock pin, or the PLL clock
output port.
This port is supported in Arria V,
Cyclone V, and Stratix V devices.
Note: For more information about DLL in Stratix V device, refer to “Delay-Locked Loop” in the External
Memory Interfaces in Stratix V Devices chapter of the Stratix V Device Handbook.
Note: For more information about PLL in Stratix V devices, refer to “PLL Specifications” in DC and
Switching Characteristics for Stratix V Devices chapter of the Stratix V Device Handbook.
UG-01089
2014.12.17
ALTDQ_DQS2 PLL and DLL Ports
33
ALTDQ_DQS2 IP Core User Guide
Altera Corporation
Send Feedback
Kommentare zu diesen Handbüchern