Seitenansicht 15
Parameter Editor GUI Setting
CLI Parameter
Description
Name
Legal Values
Name
Legal
Values
(1)
Use reset signal to
stop output strobe
USE_OUTPUT_STROBE_
RESET
true
false
This setting stops the
unidirectional output
strobe using a user-
provided reset signal. The
core_clock_in and the
reset_n_core_clock_in
signals are required.
OCT Source Output Strobe
Enable
Data Write
Enable
Dedicated
OCT Enable
OCT_SOURCE
0
1
2
This setting specifies the
type of input signal to
toggle the OCT control:
Output Strobe Enable
—Uses the output_
strobe_ena input as
the OCT control signal.
Data Write Enable
Uses the write_oe_in
input as the OCT
control signal.
Dedicated OCT
Enable—Adds a oct_
ena_in input to the
interface, which is used
as the OCT control
signal.
The availability of the
Output Strobe Enable,
Data Write Enable,and
Dedicated OCT Enable
are dependent on PIN_
TYPE and USE_BIDIR_
STROBE parameters.
Default value is Data
Write Enable.
(1)
All CLI parameter values are type string, therefore you must enclose the values in double quotes.