Assign To
Pin - PLL refclk pin
XCVR_TX_SLEW_RATE_CTRL
Pin Planner and Assignment Editor Name
Transmitter Slew Rate Control
Description
Specifies the slew rate of the output signal. The valid values span from the slowest rate to fastest rate with
1 representing the slowest rate.
Options
1–5
Assign To
Pin - TX serial data
XCVR_VCCR_ VCCT_VOLTAGE
Pin Planner and Assignment Editor Name
VCCR_GXB
VCCT_GXB Voltage
Description
Configures the VCCR_GXB and VCCT_GXB voltage for an GXB I/O pin by specifying the intended
supply voltages for a GXB I/O pin.
Options
1_1V
1_2V
Assign To
Pin - TX & RX serial data
Analog Settings Having Global or Computed Values for Cyclone V Devices
The following analog parameters have global or computed default values. You may want to optimize some
of these settings. The default value is shown in bold type. For computed analog parameters, the default
value listed is for the initial setting, not the recomputed setting. The parameters are listed in alphabetical
order.
UG-01080
2015.01.19
XCVR_TX_SLEW_RATE_CTRL
19-27
Analog Parameters Set Using QSF Assignments