4–4 Chapter 4: Development Board Setup
Factory Default Switch Settings
Stratix IV E FPGA Development Kit User Guide June 2011 Altera Corporation
3. Set DIP switch bank (SW2) to match Table 4–2 and Figure 4–1.
3 CLK100_EN
Switch 3 has the following options:
■ When on, the 100 MHz clock is disabled.
■ When off, the 100 MHz clock is enabled.
Off
4 CLK125_EN
Switch 4 has the following options:
■ When on, the 125 MHz clock is disabled.
■ When off, the 125 MHz clock is enabled.
Off
Table 4–1. SW1 Dip Switch Settings (Part 2 of 2)
Switch
Board
Label
Function
Default
Position
Table 4–2. SW2 Dip Switch Settings
Switch
Board
Label
Function
Default
Position
1DIP0
Switch 1 is a MAX II user-defined switch and has the following options:
■ When closed, a logic 0 is selected.
■ When open, a logic 1 is selected.
Closed
2DIP1
Switch 2 is a MAX II user-defined switch and has the following options:
■ When closed, a logic 0 is selected.
■ When open, a logic 1 is selected.
Closed
3DIP2
Switch 3 is a MAX II user-defined switch and has the following options:
■ When closed, a logic 0 is selected.
■ When open, a logic 1 is selected.
Closed
4DIP3
Switch 4 is a MAX II user-defined switch and has the following options:
■ When closed, a logic 0 is selected.
■ When open, a logic 1 is selected.
Closed
5DIP4
Switch 5 is a MAX II user-defined switch and has the following options:
■ When closed, a logic 0 is selected.
■ When open, a logic 1 is selected.
Closed
6DIP5
Switch 6 is a MAX II user-defined switch and has the following options:
■ When closed, a logic 0 is selected.
■ When open, a logic 1 is selected.
Closed
7DIP6
Switch 7 is a MAX II user-defined switch and has the following options:
■ When closed, a logic 0 is selected.
■ When open, a logic 1 is selected.
Closed
8 CLK66_SEL
Switch 8 has the following options:
■ When closed, the 66 MHz clock is selected.
■ When open, the SMA input clock is selected.
Closed