• Select the internal configuration scheme
• Generate the .pof with ICB settings
• Program the .pof the internal flash
Related Information
• Internal Configuration Modes on page 2-2
• Remote System Upgrade in Dual Compressed Images on page 2-8
Selecting Internal Configuration Modes
To select the configuration mode, follow these steps:
1. Open the Quartus II software and load a project using a MAX 10 device.
2. On the Assignments menu, click Settings. The Settings dialog box appears.
3. In the Category list, select Device. The Device page appears.
4. Click Device and Pin Options.
5. In the Device and Pin Options dialog box, click the Configuration tab.
6. In the Configuration Scheme list, select Internal Configuration.
7. In the Configuration Mode list, select 1 out of 5 configuration modes available. The 10M02 devices
has only 2 modes available.
8. Turn on Generate compressed bitstreams if needed.
9. Click OK.
.pof and ICB Settings
There are two methods which the .pof will be generated and setting-up the ICB. The internal
configuration mode you selected will determine the corresponding method.
Table 3-2: .pof Generation and ICB Setting Method for Internal Configuration Modes
Internal Configuration
Mode
.pof Generation and ICB
Setting Method
Description
Single Compressed
Image
Auto-generated .pof
(7)
• Quartus II will automatically generate the .pof
during project compilation
• ICB can be set in Device and Pin Options
Single Uncompressed
Image
(7)
Auto-generated .pof does not allow encryption. To enable the encryption feature in Single Compressed and
Single Uncompressed mode, use the Convert Programming Files method.
UG-M10CONFIG
2015.05.04
Selecting Internal Configuration Modes
3-5
MAX 10 FPGA Configuration Design Guidelines
Altera Corporation
Send Feedback