Table 5-8: HMC Controller IP Core INTERRUPT_STATUS Register at Offset 0x20
To clear an interrupt, write the value of 1 to the interrupt bit.
Bits Field Name Type Value on
Reset
Description
31:
16
Reserved RO 0x0000
15 Response Queue
Uncorrectable
ECC Error
W1C 0x0 The IP core sets this bit if it detects an uncorrectable ECC
error in the Response Queue memory. The IP core can
detect such an error only if you turn on Enable M20K ECC
support in the parameter editor.
14 Response Queue
ECC Error
W1C 0x0 The IP core sets this bit if it detects a correctable ECC error
in the Response Queue memory. If the IP core sets this bit it
also corrects the ECC error. The IP core can detect such an
error only if you turn on Enable M20K ECC support in the
parameter editor.
13 FERR_N W1C 0x0 The IP core sets this bit if the HMC device indicates a fatal
error by asserting its active-low FERR_N pin. You must
connect the IP core hmc_ferr_n input signal to the HMC
device FERR_N output signal.
12 Retry Buffer
Uncorrectable
ECC Error
W1C 0x0 The IP core sets this interrupt bit if it detects an uncorrect‐
able ECC error in the Retry Buffer memory. The IP core can
detect such an error only if you turn on Enable M20K ECC
support in the parameter editor.
11 Retry Buffer
ECC Error
W1C 0x0 The IP core sets this interrupt bit if it detects a correctable
ECC error in the Retry Buffer memory. The IP core
automatically corrects the ECC in this case. The IP core can
detect such an error only if you turn on Enable M20K ECC
support in the parameter editor.
10 Reserved RO 0x0
9 No More Tokens W1C 0x0
The IP core sets this interrupt bit if it runs out of tokens.
Tokens represent available buffer space in the HMC device.
While the IP core has no remaining tokens, it does not send
any additional requests, per token-based flow control
requirements. This situation is not an error condition, but it
may indicate a reduction in performance. However, like any
interrupt bit, it causes the IP core to assert the csr_irq
signal (assuming the global interrupt enable register bit is
set).
This bit has the value of 0 when the IP core comes out of
reset. After link initialization, the HMC device communi‐
cates its buffer capacity with a sequence of TRET packets.
After the IP core receives the first TRET packet, it begins
updating the No More Tokens register field.
5-6
Interrupt Related Registers
UG-01152