Chapter 2: Parameter Settings 2–3
Command Line Interface Parameters
February 2012 Altera Corporation Dynamic Calibrated On-Chip Termination (ALTOCT) Megafunction
User Guide
Command Line Interface Parameters
Expert users can choose to instantiate and parameterize the megafunction through the
command-line interface using the clear box generator command. This method
requires you to have command-line scripting knowledge.
f For more information about using the clear box generator, refer to the Introduction to
Megafunctions User Guide.
Table 22 lists the parameters for the ALTOCT megafunction.
Table 2–2. ALTOCT Megafunction Parameters
Parameter Name Type Required Description
ENABLE_PARALLEL_TERMINATION
String Yes
Enables the RT State Machine. Values are TRUE and
FALSE. If omitted, value is FALSE.
OCT_BLOCK_NUMBER
Integer Yes
The number of OCT blocks in the design. Values are
integer 1 to 10.
LPM_HINT
String No
Allows you to specify Altera-specific parameters in
VHDL Design Files (.vhd). The default value is UNUSED.
LPM_TYPE
String No
Identifies the library of parameterized modules (LPM)
entity name in VHDL Design Files (.vhd).
INTENDED_DEVICE_FAMILY
String No
This parameter is used for modeling and behavioral
simulation purposes. Create the ALTOCT megafunction
with the MegaWizard Plug-In Manager to get the value
for this parameter.