Chapter 7: Software Interface 7–7
CPRI Protocol Interface Registers
December 2013 Altera Corporation CPRI MegaCore Function
User Guide
For additional information about the
CPRI_HW_RESET
register, refer to “Reset
Requirements” on page 4–11.
reset_detect
[4] RO
Indicates that reset request has been detected in the incoming
stream on the CPRI link by the CPRI receiver.
1'h0
reset_hw_en
[3] RW
Enable generation of reset request or acknowledge by CPRI
transmitter, as indicated by the
hw_reset_assert
input signal.
This enable bit has higher priority than the
reset_gen_en
bit; if
this enable bit is set, the
reset_gen_force
bit is ignored.
Note that when a CPRI RE slave detects a reset request in
incoming CPRI communication, and the
reset_hw_en
bit is
set, the user must assert the
hw_reset_assert
input signal to
the CPRI RE slave, to force it to send a reset acknowledge by
setting the reset bit in outgoing CPRI communication at
Z.130.0.
1'h0
reset_out_en
[2] RW Enable reset output.
1'h0
reset_gen_force
[1] RW
Force generation of reset request or acknowledge by CPRI
transmitter.
1'h0
reset_gen_en
[0] RW
Enable generation of reset request or acknowledge by CPRI
transmitter, as indicated by the
reset_gen_force
bit. This
enable bit has lower priority than the
reset_hw_en
bit; if the
reset_hw_en
bit is set, this bit and the
reset_gen_force
bit
are ignored.
1'h0
Note to Table 7–12:
(1) This register field is a read-to-clear field. You must read the register twice to read the true value of the field after frame synchronization is
achieved. If you observe this bit asserted during link initialization, read the register again after link initialization to confirm any errors.
Table 7–12. CPRI_HW_RESET—Hardware Reset From Control Word—Offset: 0x20 (Part 2 of 2)
Field Bits Access Function Default
Table 7–13. CPRI_PHY_LOOP—Physical Layer Loopback Control—Offset: 0x24 (Part 1 of 2)
Field Bits Access Function Default
RSRV
[31:5] UR0 Reserved.
27'h0
loop_resync
[4] RC
(1)
Indicates that reset resynchronization is detected. This bit is
typically set when the CPRI receiver clock and
cpri_clkout
have different frequencies, as measured in the physical layer
internal loopback path.
1’h0
RSRV
[3:1] UR0 Reserved.
2'h0
Seitenansicht 122
1 2 ... 118 119 120 121 122 123 124 125 126 127 128 ... 219 220

Kommentare zu diesen Handbüchern

Keine Kommentare

Maxum Détecteurs de monoxyde de carbone (CO) manuels d'utilisation

La liste de Maxum Détecteurs de monoxyde de carbone (CO) produits contient 2 manuels d'utilisation pour les modèles 2. Tous les guides d'utilisation en format pdf peuvent être téléchargés ou consultés en ligne.

Cliquez sur un alphabet ci-dessous pour faire défiler la liste complète des modèles commençant par cette lettre

Modèles Type de document
1800MX
Spécifications   Maxum 1800MX Specifications, 96 pages
2400 SC3
Spécifications   Maxum 2400 SC3 Specifications, 56 pages