Chapter 6: Board Test System 6–15
Using the Board Test System
July 2013 Altera Corporation DSP Development Kit, Stratix V Edition
User Guide
HF2—Selects second lowest frequency divide-by-22 data pattern
LF—Selects lowest frequency divide by 33 data pattern
Error Control
The Error control controls display data errors detected during analysis and allow you
to insert errors:
Detected errors—Displays the number of data errors detected in the hardware.
Inserted errors—Displays the number of errors inserted into the transmit data
stream.
Insert Error—Inserts a one-word error into the transmit data stream each time you
click the button. Insert Error is only enabled during transaction performance
analysis.
Clear—Resets the Detected errors and Inserted errors counters to zeros.
Start
The Start control initiates the active port transaction performance analysis.
1 Always click Clear before Start.
Stop
The Stop control terminates transaction performance analysis.
Performance Indicators
These controls display current transaction performance analysis information collected
since you last clicked Start:
TX and RX performance bars—Show the percentage of maximum theoretical data
rate that the requested transactions are able to achieve.
Tx (MBps) and Rx (MBps)—Show the number of bytes of data analyzed per
second.